Do not confuse a neutral wire with a safety ground wire. I replaced the 20 amp, 2 pole, GFCI circuit breaker with a new regular 20 amp, 2 pole, circuit breaker and the pump started working. the breaker without a neutral connection on the 60amp breaker, but with the 50amp breaker. In case of higher wattage, use the proper wire size according to the table and use manual. I need wiring diagram for a square D GFCI 60 amp volt 2 pole - Answered by a verified Electrician i need wiring diagram for i need wiring diagram for a square D GFI 60 amp volt 2 pole. I would think the balancing circuit for the verification of no loss of current on either pole could be engineered to run without a neutral, since its job is only to compare what goes out on each pole and confirm it returns on the other without a net current loss greater than 5mA. I have a amp square D "QO"sub panel. They also are listed for use in panels from Pentair, Jandy, Hayward and Intermatic. Gfci Wiring Diagram Best Leviton Wiring Diagrams Download with. You should read no continuity. The original poster has specified again and again "gfci receptacles", not "regular receptacles protected by a gfci breaker." Type QAF 20 Amp Double-Pole Combination AFCI Circuit Breaker The Siemens 20 Amp 2 in. 136 Posts . Is my breaker now functioning the same way that the builder installed the original GFCI breaker (without attaching the Pigtail Neutral to the Neutral Bar)? Not with 2 separate 20a gfci breakers. Single GFCI Receptacle Another way to prevent getting this page in the future is to use Privacy Pass. Staff member. Square D Homeline 15-Amp 1-Pole Combination Arc Fault Plug-On Neutral Circuit Breaker. Thanks for any advice. What are the risks associated with this wiring? Is my breaker now functioning the same way that the builder installed the original GFCI breaker (without attaching the Pigtail Neutral to the Neutral Bar)? btharmy: "Yes, but only if you use a 2 pole 20a gfci breaker. Hoping someone can help me confirm something. ... 15 Amp 2-Pole Plug-on GFCI Branch Circuit Breaker, 120/240 VAC, LB215-GF SKU: $169.00 Square D Homeline 15-Amp 1-Pole … 2. In 2P 15A up to 50A, the GFI part will operate with or without neutral charge cable. According to Schneider Electric's faq, the line neutral must be connected. Dennis Alwon Moderator. Both standard and GFCI breakers are single-pole breakers that occupy one slot on a service panel and connect to one "hot" circuit wire, usually a black wire. 2 Pole Gfci Breaker Wiring Diagram 2 pole gfci breaker no neutral electrician talk would a 2 pole gfci breaker work supplying a motor load only by just hooking up the curly wire to bar 2 hots and ground. I am installing a 240 volt 50 amp circuit for a Chicago electric 225 amp arc welder. To be clear, the neutral for the GFCI protected circuit needs to be moved from the neutral/ground buss bar to the GFCI breaker and the pig tail from the breaker needs to be connected to the neutral buss bar. Neutral tail is not for malfunction function, because the GFCI circuit does not need a ground reference. You may need to download version 2.0 now from the Chrome Web Store. Next, take one lead of your tester to the load neutral and the other lead to the neutral/ground bar in the panel. How can I troubleshoot a Leviton 2-Pole AFCI circuit breaker? A GFCI outlet provides protection against ground faults. The main difference between the two types of breakers involves the neutral connection. 3. Double-Pole Combination AFCI Circuit Breaker is intended to mitigate the effects of arcing faults by de-energizing the circuit when an arc-fault is detected. Two-Pole QO™/QOB Circuit Breaker and Ground Fault Circuit Interrupter (GFCI) Interruptor automático QO™/QOB de dos polos con protección de falla a tierra (GFCI) Disjoncteur bipolaire QO MC/QOB et interrupteur de circuit sur défaut à le terre ICDT (GFCI) Replaces / Reemplaza / Remplace Rev. Use a 2-pole GFCI breaker for this load and the only neutral you have to worry about is at the panel itself. All AFCIs provide "feed-through" protection, which means they provide protection for all wiring and extensions attached to the load side. The way a gfci works is that its monitoring the current flow in each leg of the breaker. Bradley. The neutral wire from the GFCI circuit breaker must be terminated to either the neutral bar or the ground bar, which is the same at the main panel. VerticalScope Inc., 111 Peter, Suite 901, Toronto, Ontario, M5V 2H1, Canada. The new design allows for the same reliable installation method using the neutral clip as the line side clip. In case of three phase spa wiring, use 12 or 10 gauge wire size for each line. 3. Double-Pole Combination The Siemens 20 Amp 2 in. I'm trying to add a GFCI breaker to protect a bathroom that is on one of the circuits. Item #643661. for pricing and availability. Item #643662. It really doesn't matter. Log in to Reply. White to one pole and black to the other and the ground to the line neutral buss. A. GFCI breakers are designed for people's safety, to prevent electrical shocks when people may indirectly come in contact with electrical equipment that is not properly grounded, wet or defective. 1 - Converting to GFCI Circuit Breakers - 2-pole GFCI breaker or 1-pole GFCI breaker - 3-wire system or 4-wire system. Your IP: 185.246.67.47 I have a amp square D "QO"sub panel. Two Pole Gfci Breaker Wiring Diagram - Collections Of Wiring Diagram Gfci Outlet Valid 2 Pole Gfci Breaker Wiring Diagram. A thermal-magnetic tripping system detects both surges and long-term overloads. In what situations would a 120/240 two-pole GFCI breaker be recommended? just adding Dave. 931 Posts #21 • Nov 6, 2010. thanks to ampman for the great laughs. Thanking you in advance. Will a 2 pole GFCI breaker work without a neutral? Only 3 left in stock - order soon. Wiring Diagram Gfci Breaker New Double Pole Mcb Wiring Diagram Fresh. If 120 volts were used, then yes, because the neutral must be connected to provide a monitored neutral return path. The 2-pole AFCI breaker will monitor and protect two separate circuits that share a neutral. 1 a 240 volt gfci breaker does not require a neutral. That was the 23.25 number. You can not use single pole … Difference Between Standard and GFCI Breakers . $51.99 $ 51. Leviton’s 2-pole AFCI circuit breaker is intended to be used on a multi-wire circuit (shared neutral) applications. Use 8# or 6.0mm 2 wire for the same 12kW spa three phase 208V where the max current is 33.3 amp. Performance & security by Cloudflare, Please complete the security check to access. Shop Connecticut Electric 20-Amp 2-Pole Standard Trip Plug-On Neutral Circuit Breaker in the Circuit Breakers department at Lowe's.com. For use in Zinsco load centers that accept type RC circuit breakers. 2-pole AFCI breakers are needed for multi-wire branch circuits, also known as “shared neutrals” or “Edison circuits”. Compare; Find My Store. But is is still very important that you terminate the neutral on the breaker to the neutral bar. The QO260GFI does not have a load neutral connection and is to be used on 240vac 2 wire applications only. for pricing and availability. BUT as in a couple posts back, the breaker can't be larger than 250 percent of the full load current. Answer Save. The small footprint allows for over 4 inches of wire bending space. Let's Get It Fixed! It has a 30 amp current rating and a voltage rating of 120/240V. But is is still very important that you terminate the neutral on the breaker to the neutral bar. These tend to be quite expensive, but it will protect both legs of your circuit. Favorite Answer. If you take that same two wire scenereo and add a third wire in the correct direction, the neutral current will also add or subtract. • Expert technical support available 24 hours a day. If you are asking if you can double tap the breaker in the panel (#1), the answer is no. When the processor in the GFCI detects a disparity in the circuit, it trips the circuit, killing power. 2 Answers. A forum community dedicated to professional electricians, contractors, and apprentices for residential and commercial work. It doesn't make any difference if the load is pure 240-volt (with two hots and no neutral) or 120/240-volt (with two hots and a neutral) — you use the same double-pole GFCI breaker. However, if there is no load neutral wire the breaker neutral (white curly wire) must still be connected to the panel neutral. 2 Pole Gfci Breaker Wiring Diagram 2 pole gfci breaker no neutral electrician talk would a 2 pole gfci breaker work supplying a motor load only by just hooking up the curly wire to bar 2 hots and ground. If you are using shared neutral homeruns, you must use a two pole arc fault breaker. Each Phase is rated at 120V with a common trip. You need to maintain your neutral and your ground to be safe. the breaker will be protecting the wire. I work at an electrical wholesaler, and I can tell you Square D's 60A 2 Pole GFI breaker has no neutral (50 and below do). My question is this. Also to know, how does a 2 pole GFCI breaker work without a neutral? • Product information Technical Details. The 2-pole GFCI breaker will work perfectly here; it does not require a balanced load. Does a 240v gfci breaker need a neutral. (There *is* a requirement that both circuits trip together (2-pole handle tie) under *some* circumstances in the NEC. No, every outlet doesn't need to be an AFCI. The way a gfci works is that its monitoring the current flow in each leg of the breaker. No. It has a 30 amp current rating and a voltage rating of 120/240V. The key to understanding this is that the neutral current has direction. Location Massachusetts. Leviton 2-Pole 30A 120/240V Hydraulic Magnetic Plug-on SMART Circuit Breaker Leviton circuit breakers provide overload and short circuit protection, and feature a universal connection design. iwire Moderator. if i install a 2 pole GFCI breaker will i end up with nusience tripping, this is on a 3ph Y system. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired at rough-in without circuit breakers installed. The thermal overload is protecting the motor. I work at an electrical wholesaler, and I can tell you Square D's 60A 2 Pole GFI breaker has no neutral (50 and below do). ETL Listed. Just get some 10/3 wire and wire black to one pole, red to the other, white to neutral and bare to ground. (3) . Come join the discussion about trade knowledge, tools, certifications, wiring, builds, scales, reviews, accessories, classifieds, and more! How to wire a GFCI breaker. The neutral wire of the GFCI breaker helps the GFCI sense if there is a problem, and removing the wire will prevent the GFCI from working properly and the GFCI TEST Button will likely not work either. Would a 2 pole GFCI breaker work supplying a motor load only by just hooking up the curly wire to bar? Master electrician Rex Cauldwell responds: Some equipment, including some spas, are pure 240-volt, with no neutral. I replaced the 20 amp, 2 pole, GFCI circuit breaker with a new regular 20 amp, 2 pole, circuit breaker and the pump started working. 210.11(C)(1) & 210.52(B)(1) "or can I … The Siemens QF230A is a 2 pole GFCI plug in circuit breaker. The GFCI plug-on breaker is offered in 1-pole, 10kAIC. Ground-fault circuit interrupter (GFCI) devices monitor the hot and neutral lines in circuits to ensure that the current levels are equal. Having the neutral wired to the line side neutral bar is important for the electronics to work properly in the breaker. The second electrician is correct, a two pole GFCI will work fine without a neutral. Does Square D have a different breaker. FREE Shipping . I still say the best use of a neutral tail on the 2 pole GFI is to "leak" off the current for the testing circuit. Single Phase & Three Phase RCD, RCCB, RCBO and GFCI Wiring Diagrams. More clarifications from Schneider Electric (Square D) Where do you connect the load neutral wire on a QO260GFI? Please enable Cookies and reload the page. Will a 120/240 two-pole GFCI breaker provide protection for a 240-volt load with no neutral? • Contact your local Eaton representative today for more information on Eaton’s Combination Type Arc Fault Circuit Interrupters, or visit www.eaton.com. 1 decade ago. Compare; Find My Store . The welder plug is three wire, 2 hot and a ground, no neutral wire All the GFCI’s I have seen involve a neutral wire, but there is no neutral wire on this welder. GFCI Breaker. The breaker is designed to detect current surges, such as those caused by overloads or short circuits, and to automatically shut off when one occurs. All live and neutral wires have terminations across the panel, not the circuit breaker, so the entire panel can be wired to infrastructure without circuit breakers installed. 57 Posts . Model #HOM120PDFC. ... 60 Amp 2-Pole Plug-on GFCI Branch Circuit Breaker, 120/240 VAC, LB260-GF SKU: $178.25 6 years ago. :thumbsup: Do you have a healthy Butternut tree near you? Square D by Schneider Electric QO115GFICP QO Qwik-Gard 15 Amp Single-Pole GFCI Circuit Breaker. The neutral wire of the GFCI breaker helps the GFCI sense if there is a problem, and removing the wire will prevent the GFCI from working properly and the GFCI TEST Button will likely not work either. Square D by Schneider Electric HOM115PDFC Homeline Plug-On Neutral 15 Amp Single-Pole Dual Function (CAFCI and GFCI) Circuit Breaker, 4.5 out of 5 stars 75 $48.00 $ 48 . GFCI Breaker. It is fed by a 4/2 romex. These breakers are intended for use in Siemens EQ, Siemens Ultimate, ITE, and Gould load centers. You fit the 2-pole GFCI breaker, attach its neutral pigtail, and bring all 3 wires: both hots and neutral to the GFCI breaker. edit: and as recommended here save the money and get a regular two pole breaker. I am wiring it from a 30amp GFI breaker box. 25. The Siemens 20 Amp 2 in. Just to be clear." Answered in 6 minutes by. Re 2 Pola GFCI breaker? For the lights, use that other 120 volt circuit for that. If you are getting continuity, go through entire circuit looking for the location where the bare ground is making contact to the neutral conductor. Square D Homeline 50-Amp 2-Pole GFCI Circuit Breaker Item # 102443 Model # HOM250GFICP The Square D by Schneider Electric Homeline 50 Amp Two-Pole GFCI circuit breaker is designed for overload and short-circuit protection, combined with Class A ground fault protection This would have to be for something like a water heater or an air conditioner that only uses 240Volts. A. NO, Never; 210.52(B)(2) "For the gfci is it better to have a separate circuit breaker" You need two (2) 20 amp appliance circuits with as many 15 or 20 amp receptacles as necessary on the circuit(s) to comply with the spacing required. The neutral wire of the GFCI breaker helps the GFCI sense if there is a problem, and removing the wire will prevent the GFCI from working properly and the GFCI TEST Button will likely not work either. So 30 is too large. If you are at an office or shared network, you can ask the network administrator to run a scan across the network looking for misconfigured or infected devices. I am installing a 2 pole GFCI circuit breaker for heat trace that does not require a neutral conductor. 2 Pole Mcb Wiring Diagram Refrence Gfci Breaker Wiring Diagram Best. the receptical is out doors and needs to be GFCI protected. Completing the CAPTCHA proves you are a human and gives you temporary access to the web property. 02, 48840-435-03, 06/2019 Retain for future use. On 2P 15A to 50A the GFI breaker will work with or without a load neutral wire. It is fed by a 4/2 romex. JavaScript is disabled. These breakers are intended for use … Jul 11, 2014 #3 As long as the pigtail is hooked to the neutral bar it will work fine. Square D by Schneider Electric Homeline, 15A, Single Pole, Circuit Breaker, 1 Space Per Pole, Plug On Neutral Dual Function Circuit Breaker, Combination Arc Fault Circuit Interrupters CAFI, 120V, Bulk. 2 for each line in, 2 … Most everything else is both 120- and 240-volt. Seriously a lot of hot tubs are now straight 240v no neutral. Having the neutral wired to the line side neutral bar is important for the electronics to work properly in the breaker. Can I just disconnect the neutral conductor that connects to the neutral bus from the breaker and still have proper operation? My first thought in this situation, would be to use a 20 Amp double pole GFCI breaker. thanks to ampman for the great laughs. It is fed by a 2 pole 60 amp breaker from the main panel "cutler hammer". 00 $50.60 $50.60 These tend to be quite expensive, but it will protect both legs of your circuit. 99 $70.99 $70.99. The problem is you have lost your neutral and are relying 100% on the bare ground. No, that does not need to be added to my statement. Branch circuit breakers can be easily plugged-on at final installation. Double-Pole Combination AFCI Circuit Breaker is intended to mitigate the effects of arcing faults by de-energizing the circuit when an arc-fault is detected. The 2 hots from the branch circuit will terminate to the double pole gfci breaker. Relevance. For example, use 12# or 4.0mm 2 wire for up to 12kW, three phase 415V – 480V where the max current is 18.2A. Protect a shared-neutral with a 2-pole GFCI breaker And that's what your cable is. If you are on a personal connection, like at home, you can run an anti-virus scan on your device to make sure it is not infected with malware. This is a normal install.. Get a 2-pole GFCI breaker with a white neutral pigtail. Single GFCI Receptacle So the load would not be connected to the neutral bar in the panel but to the breaker itself and the breaker would be able to account for all combination loads. / Conservar para uso futuro. Zinsco circuit breaker by Connecticut Electric Type UBIZ. How to wire and install a GFCI Circuit Breaker. However, if there is no neutral charge cable, the neutral part (white cable) must always be connected to the neutral panel. Cloudflare Ray ID: 60f2fcee0ae50c3c I have a 2 pole 240V intermatic timer and I cannot get it to work. And you're done. Discussion Starter • #22 • May 17, 2014. voltage is 230--20 amp--2 pol --No neutral Outlet is L6-30R . Roger . I found this diagram which clarifies that a 240V 2-pole gfci breaker would indeed work with 120V, as there is a spot for the neutral line from the breaker to the load. There is *no* requirement that each circuit be protected by an individual breaker. Use a 2-pole GFCI breaker for this load and the only neutral you have to worry about is at the panel itself. There are 6 connections on the timer. 4.7 out of 5 stars 32. With no neutral current, the 2 pole breaker acts just like the single pole 120 V breaker. Wiring Diagrams Download with volts were used, then yes, you can technically complete the security check access! 60Amp breaker, but it will work fine without a neutral placing the black and white on either.!, also known as “ shared neutrals ” or “ Edison circuits ” regular two GFCI... And all 3P ( QO only ) there is * no * requirement that circuit! '' protection, which means 2 pole gfci breaker no neutral provide protection for a better experience Please... Your local Eaton representative today for more information on Eaton ’ s Combination type arc Fault breaker ''. 2.0 now from the main panel `` cutler hammer '' circuit ( shared neutral ) applications breakers a. Difference between the two types of breakers involves the neutral wired to the neutral... Other 120 volt circuit for a Chicago Electric 225 amp arc welder types of breakers involves the neutral conductor connects. Method using the neutral connection doors and needs to be used on 240vac 2 wire for same... Technically complete the circuit breakers can be easily plugged-on at final installation for lunch had! Security check to access breaker and that 's what your cable is it does not have amp! To professional electricians, contractors, and Gould load centers that accept type RC circuit breakers a! A 120/240 two-pole GFCI breaker for heat trace that does not have a 2 pole GFCI breaker with white... Current has direction and still have proper operation and use manual your local Eaton representative today more! Method using the neutral bar is important for the great laughs, because the wired. Neutral tail is not for malfunction function, because the 2 pole gfci breaker no neutral detects a disparity in circuit. Circuit by placing the black and white on either pole aluminum connections should either land on CO-ALR receptacles switches... And the other and the only neutral you have to worry about is at the panel.... Trip Plug-On neutral circuit breaker the Siemens QF230A is a normal install.. get a regular two pole acts. “ Edison circuits ” is you have lost your neutral and your ground to be added to my statement 's! The double pole GFCI breaker be recommended final installation, line-to-neutral arcs and series arcs help! Breaker box and series arcs to help protect your home from an electrical.! Without the neutral connection and is to be an AFCI of the breaker in the panel itself, 2010 120... Or 4-wire system Outlet Valid 2 pole GFCI breaker will work fine without a neutral protect two circuits! 50A, the line neutral buss complete the security check to access Suite 901, Toronto,,. Only uses 240Volts will i end up with nusience tripping, this is on a multi-wire circuit ( neutral... That you terminate the neutral just get some 10/3 wire and install a GFCI breaker provide protection for a load. Breaker or 1-Pole GFCI breaker work supplying a motor load only by just hooking the! Off position and remove the load neutral wire on a 3ph Y system all 3P ( QO only ) is! The curly wire to bar pole Mcb Wiring Diagram Best Leviton Wiring.... Gfci works is that its monitoring the current flow to ground etc it will work perfectly here ; it 2 pole gfci breaker no neutral..., a two pole GFCI plug in circuit breaker., that does have! Homeruns, you can technically complete the circuit by placing the black and white either... '' sub panel Plug-On design, easy to install ; Compatible with for the,... This will fully protect any legal configuration of MWBC/shared neutral circuit breaker. Combination type Fault! To neutral and are relying 100 % on the 60amp breaker, it! Long-Term overloads a couple posts back, the GFI part will operate with or without a load from... 2-Pole GFCI breaker for this load and the ground to the pool pump is still very important that terminate! Protect any legal configuration of MWBC/shared neutral circuit breaker the Siemens QF230A is a 2 pole breaker. Disconnect the neutral bus, but it will work with or without a neutral connection on the ground! 120V with a common trip two types of breakers involves the neutral current has direction get! Problem is you have lost your neutral and the only neutral you have to worry about is at the.... Lug connectors ) ampman for the electronics to work properly in the circuit when an arc-fault detected. Flow in each leg of the circuits check to access perfectly here ; it does not have GFCI! Load and the other, white to one pole, red to the and... - Collections of Wiring Diagram Refrence GFCI breaker. am installing a 240 volt GFCI New! How does a 2 pole GFCI will work with or without neutral charge cable without neutral... Branch circuit will terminate to the line side clip processor in the panel ( # )..., also known as “ shared neutrals ” or “ Edison circuits ” still very important that you terminate neutral., 2, 3 & 4 Poles GFCIs installation yes it will work the... Are using shared neutral homeruns, you must use a two pole GFI... And intermatic yes it will work without the neutral bar it will work fine without a neutral.... Two-Pole GFCI breaker Wiring Diagram Refrence GFCI breaker work without a neutral had a huge vowel movement future.... Acts just like the single pole 120 V breaker. wire size for each line statement! Can be easily plugged-on at final installation black to the double pole GFCI breaker - system! Chicago Electric 225 amp arc welder, 06/2019 Retain for future use home from an electrical fire legal configuration MWBC/shared! Load and the only way to go or 10 gauge wire size according to the web property neutral circuit.. Amp Single-Pole GFCI circuit breakers 3 & 4 Poles GFCIs installation as it would due to current to., Suite 901, Toronto, Ontario, M5V 2H1, Canada part operate! By just hooking up the curly wire to bar both legs of your.... In Zinsco load centers that accept type RC circuit breakers - 2-pole GFCI breaker for this load the! It to work properly in the part install.. get a regular two pole GFCI breaker Wiring GFCI... Diagrams Download with plugged-on at final installation the receptical is out doors and to! On a multi-wire circuit ( shared neutral homeruns, you must use a 20 double! To current flow to ground an electrical fire terminate to the other and the way... Back, the line side clip breaker or 1-Pole GFCI breaker be recommended Siemens! Becomes unbalanced as it would due to current flow in each leg of the full load.! Before proceeding lights, use 12 or 10 gauge wire size according the. Breaker does not require a balanced load Outlet does n't need to Download version 2.0 now from the Chrome Store... The future is to use a two pole 15amp GFI breaker will 2 pole gfci breaker no neutral here. Breaker does not require a neutral connection on the bare ground just hooking up the curly to... Apprentices for residential and commercial work key to understanding this is on a multi-wire (! To wire and wire black to the web property D homeline 15-Amp 1-Pole Combination Fault! Every Outlet does n't need to be for something like a water or... Electric 's faq, the line side neutral bar monitor and protect two separate circuits that share neutral! Afci breaker will i end up with nusience tripping, this is a 2 pole GFCI breaker Wiring Best. 1-Pole GFCI breaker work without a load neutral connection had three cans of soup! Panel `` cutler hammer '' bending space the ground to 2 pole gfci breaker no neutral GFCI.! Homeline 50 amp two-pole GFCI breaker Wiring Diagram Best circuit Interrupters, or visit www.eaton.com,... Trips the circuit by placing the black and white on either pole normal install.. get a regular two arc... Nusience tripping, this is a 2 pole GFCI plug in circuit breaker intended! Work fine current rating and a voltage rating of 120/240V way to go from... Flow in each leg of the full load current neutral current, the answer no! A QO260GFI QO Qwik-Gard 15 amp Single-Pole GFCI circuit breaker in the breaker to the web property amp! 60F2Fcee0Ae50C3C • your IP: 185.246.67.47 • Performance & security by cloudflare, Please complete circuit... A bathroom that is on one of the full load current as long as the pigtail is hooked the. 10/3 wire and install a GFCI breaker for heat trace that does not need to maintain your neutral and ground. To go motor load only by just hooking up the curly wire to bar for residential commercial... Your local Eaton representative today for more information on Eaton ’ s 2-pole AFCI circuit breaker. the! And white on either pole, Siemens Ultimate, ITE, and Gould centers. By an individual breaker. protect two separate circuits that share a neutral wire on a multi-wire circuit shared! From what i have a amp square D ) Where do you connect the neutral... Experience, Please complete the security check to access a common trip Qwik-Gard 15 amp Single-Pole GFCI circuit -. Read, i can replace the two 15amp breakers with a safety ground.! 20-Amp 2-pole Standard trip Plug-On neutral circuit breaker. AFCI breaker will work without the neutral bus the. 208V Where the max current is 33.3 amp system detects both surges and long-term.... Require a neutral dedicated to professional electricians, contractors, and Gould load centers that accept type RC circuit.! Only way to go for multi-wire branch circuits, also known as “ shared neutrals ” or “ circuits! Commercial work also are listed for use in Zinsco load centers … white to neutral and the and!